Fire Alarm Installation London from £209.99/alarm

from£209.99

Mains-wired interlinked · BS 5839-6 compliant · Free survey · Commissioning certificate included

Per alarm

£209.99

System type

Grade D LD2

Certificate

Included

Standard

BS 5839-6

Mains-wired fire alarm installation for London HMOs

New HMO licences across all London boroughs require mains-wired interlinked smoke and heat alarms throughout the property. When any one alarm is triggered, all alarms sound simultaneously — giving occupants maximum warning time regardless of where the fire starts. Battery-only alarms are no longer acceptable for new HMO licence applications in most London councils.

We install Grade D, LD2 mains-wired systems using Aico and FireAngel — market-leading brands with 10-year sensor life and sealed backup batteries. Each alarm draws power from the mains and has a sealed backup battery, ensuring it continues to function even during a power cut.

Pricing is per alarm including supply, installation, interconnection wiring, and commissioning. We provide a free pre-installation survey to determine the exact number and specification of alarms required for your property.

How it works

1

Free survey

Our engineer visits your property, identifies the number and positions of alarms required under BS 5839-6, and assesses cable routes. You receive a fixed-price quote for the full installation.

2

Installation (1–2 days)

We install and wire all mains-wired alarms, interconnect them, and test each alarm including the full interlink — any alarm activated should trigger every other alarm in the system.

3

Commissioning certificate

You receive a BS 5839-6 commissioning certificate confirming the system is installed and fully functional. Suitable for HMO licence applications and local authority inspection.

Pricing

£209.99per alarm

Individual alarm installation

Supply and installation per mains-wired alarm. Most 1–3 bed properties need 4–6 alarms.

£3499full system

Full system installation

Complete Grade D LD2 system for a typical 1–3 bed property. Includes all alarms, wiring, and commissioning.

A free survey confirms the exact number of alarms needed. Final price agreed before installation begins.

  • · All alarms interconnected (hard-wired or RF)
  • · BS 5839-6 commissioning certificate included
  • · Additional charges: Congestion Zone +£20 · Parking +£10

What's included per alarm

  • Mains-wired Grade D alarm (Aico or FireAngel)
  • Sealed backup battery
  • Interlinked with all other alarms on circuit
  • Correct positioning per BS 5839-6
  • Full commissioning and interlink test
  • BS 5839-6 commissioning certificate
  • Suitable for HMO licence submission
  • Free pre-installation survey

Types of fire alarm systems we install

Fire alarm systems for residential and commercial properties are classified by two separate grading systems: Grade (the type of power supply and interconnection) and Category (the extent of coverage). Understanding both is essential for meeting your HMO licence conditions and the requirements of BS 5839-6.

Grade A

Fully addressable commercial systems (BS 5839-1)

Grade A systems are the commercial standard — a fully addressable panel with zone mapping, automatic detection throughout the building, and manual call points at all exits. When a detector activates, the panel pinpoints its exact location. Grade A systems are required for large commercial premises, care homes, hotels, and high-rise residential buildings. They are designed, installed, and commissioned to BS 5839-1 and must be maintained under a service contract. If your property is a block of flats or converted building with communal areas, a Grade A system may be required for the communal parts even if individual flats have Grade D systems.

Grade D

Mains-powered interlinked alarms (BS 5839-6)

Grade D is the standard for most HMOs and residential lettings in London. Grade D alarms draw power from the mains supply and have a sealed backup battery — so they continue to function during a power cut. When one alarm activates, all others sound simultaneously. Grade D1 means hard-wired interconnection via cable; Grade D2 uses radio frequency (RF) wireless interconnection between alarms. Hard-wired (D1) is preferred where cable runs are practical, but RF (D2) is acceptable and often used in retrofit installations where running cables would cause significant disruption. New HMO licences in all 33 London boroughs now require Grade D as a minimum — battery-only alarms are no longer accepted for new or renewed licences in most areas.

Coverage categories — LD1, LD2, LD3

LD1 — Full property coverage

Detectors installed in all rooms and areas of the property, including bedrooms, living rooms, kitchens, bathrooms, utility rooms, and all circulation areas. The most comprehensive residential protection level. Required by some London boroughs for larger HMOs (5 or more occupants) and for high-risk properties such as those with complex layouts or multiple floors. Some boroughs — including Hackney and Tower Hamlets — require LD1 for all licensable HMOs.

LD2 — Escape routes plus high-risk rooms

Coverage in all escape routes (hallways, landings, stairwells) plus principal habitable rooms — bedrooms and living rooms — and heat detectors in kitchens. LD2 is the most common HMO requirement across London boroughs, including Southwark, Lambeth, Wandsworth, Brent, Ealing, Camden, and most other boroughs. It provides detection where a fire is most likely to start and along the routes occupants must use to escape.

LD3 — Escape routes only

Detectors only in circulation areas — hallways, landings, and stairwells. LD3 is the minimum standard under the Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022, which require at least one smoke alarm on every floor of a rented property. However, LD3 alone is insufficient for HMO licensing in most London boroughs — the typical minimum for an HMO licence is LD2.

Borough-specific requirements: London borough HMO licensing conditions vary. As a guide, most boroughs require Grade D LD2 as the minimum for a standard licensable HMO, with Grade D LD1 required for larger HMOs or those with specific risk factors. Always check your borough's current HMO licensing conditions — our engineer will confirm the exact specification required during the free pre-installation survey.

Fire alarm legal requirements for London landlords

The legal obligation to install and maintain adequate fire detection in rented properties arises from several overlapping pieces of legislation. Understanding which applies to your property is essential for compliance.

Smoke and Carbon Monoxide Alarm (Amendment) Regulations 2022

These regulations — in force since October 2022 — require all private landlords in England to install at least one smoke alarm on every storey of their rental property where there is a room used as living accommodation, and a carbon monoxide alarm in any room with a fixed combustion appliance (excluding gas cookers). Alarms must be tested at the start of each new tenancy. Failure to comply can result in a local authority remedial action notice and a fine of up to £5,000. These regulations apply to all rented properties — not just HMOs.

Housing Act 2004 — HMO Management Regulations

The Management of Houses in Multiple Occupation (England) Regulations 2006 require the manager of an HMO to ensure that all means of escape from fire are maintained in good order and repair, and that all fire detection and fire-fighting equipment is maintained in proper working order. The HMO licensing regime under the Housing Act 2004 adds a further layer: local authorities set specific conditions as part of the HMO licence, which almost always include detailed fire alarm specifications (Grade, category, and number of alarms) that go beyond the minimum set by the 2022 Regulations.

Regulatory Reform (Fire Safety) Order 2005

The Fire Safety Order imposes duties on the "Responsible Person" — typically the landlord or their managing agent — to carry out a fire risk assessment and implement appropriate fire safety measures, including adequate means of detection and warning. For HMOs and buildings with communal areas, the Order requires a written fire risk assessment and a documented fire detection system that is appropriate to the risk. This is a separate obligation from the 2022 Regulations and the HMO licence conditions — all three must be met simultaneously.

London borough HMO licensing conditions

Every London borough sets its own HMO licence conditions, and these typically specify the fire alarm grade and category in detail. Most boroughs now require Grade D LD2 as the minimum for a standard licensable HMO. Some boroughs require LD1 for larger properties. The conditions also specify alarm positions, testing frequencies, and documentation requirements. Non-compliance with licence conditions can lead to revocation of the HMO licence — making the property unlawful to let — and fines of up to £30,000. Always confirm your specific borough's requirements before installing.

The Responsible Person's testing obligations

Once installed, the fire alarm system must be maintained. BS 5839-6 requires that the Responsible Person (landlord or their agent) tests each alarm monthly by pressing the test button, and arranges for an annual inspection and test by a competent person. The annual test must be documented. For HMOs, this documentation must be retained and produced on request during a local authority inspection. Our annual fire safety certificate service provides the required annual inspection and certificate from £54.99.

BS 5839-6 compliance explained

BS 5839-6 is the British Standard that governs the design, installation, commissioning, and maintenance of fire detection and alarm systems in domestic premises. It is the primary technical reference for all residential fire alarm work in the UK — including HMOs, houses, flats, and residential care homes. A separate standard, BS 5839-1, applies to commercial premises and larger non-domestic buildings.

The standard specifies everything from the minimum number and positioning of detectors in each room type, to cable specifications, interconnection requirements, alarm sound levels, and commissioning procedures. A system installed "to BS 5839-6" means that every aspect of the design and installation has been carried out in accordance with the Standard's requirements — not simply that a smoke alarm has been put on the ceiling.

Upon completion, we issue a BS 5839-6 commissioning certificate. This document confirms: the system has been designed to the correct Grade and Category for the property; all alarms have been installed in the correct positions; the interlink has been tested and verified (every alarm activates all others); and the system has been handed over to the Responsible Person with instructions for testing and maintenance. The commissioning certificate is accepted by all London local authorities as evidence of compliance for HMO licence applications and renewals.

There is no fixed expiry date on a BS 5839-6 commissioning certificate — it confirms the state of the system at the time of installation. However, the annual maintenance inspection is a separate requirement under the Standard, and local authorities may require an annual fire safety certificate (confirming the system has been tested and is still functional) as part of ongoing HMO licence compliance. We provide this annual certificate from £54.99 — see our fire safety certificate service for details.

Frequently Asked Questions

Related services

Book your fire alarm installation

£209.99 per alarm installed. Free survey to confirm how many alarms you need. Certificate included. All 33 London boroughs covered.